Picture of Tray Cable ShieldedTRAY CABLE SHEILDED VNTC®* - PVC Jacket
PVC/Nylon Insulation 90°C
600 Volt - UL Type TC


Construction
Conductor: - Stranded bare copper Class B per UL 83.
18 AWG
16 AWG
14 AWG
12 AWG
10 AWG
Insulation: -

(18 AWG and 16 AWG) Extruded polyvinyl chloride (PVC) to UL requirements for Class TFN and TFFN insulation with nylon jacket is approved per UL 83.

14 AWG, 12 AWG, and 10 AWG) Extruded polyvinyl chloride (PVC) to UL requirements for Class THHN and THWN insulation with nylon jacket is approved per UL 83.

18-12 AWG = Insulation Thickness: .015", Nylon Thickness: .004".

10 AWG = Insulation Thickness: .020", Nylon Thickness: .005".

Shield: - 100% aluminum polyester with tinned copper drain wire.
Assembly: - The conductors are cabled with fillers where needed to make a round compact core and a suitable tape (when required) is applied over the construction.
Conductor Identification:   Color coded per Method 1 (E-2)
Jacket: - Black sunlight resistant, flame retardant polyvinyl chloride (PVC) per UL 1277 requirements for Type TC power and control cables.
Applications: -

Control circuits for operation and interconnection of protective and signaling devices, and for general use in manufacturing, industrial, and commercial distribution systems.

UL listed and labeled for installation in ladders, trough, channels, solid bottom trays and other similar structures (NEC Articles 318 and 340), and in duct, conduit, wireways and all other installations approved for building wire.

In hazardous locations per NEC Articles 500 and 501. May be used in wet or dry locations, sunlight resistant, and suitable for direct burial.

Standards: - UL Type TC, 600 Volt.
NEC Type TFN Conductors (18 & 16 AWG)
NEC Type THHN / THWN Conductors (14 - 10 AWG)
IEEE 1202 (70,000 BTU/hr) / CSA FT4.
IEEE 383 (70,000 BTU/hr).
UL Subject 1277 (70,000 BTU/hr).
OSHA Acceptable.

18 AWG - Stranding Bare Copper - Get Quote
P/N # Of Cond. Nom. Insulation
Thickness (Inches)
Nom. O.D. (inches) Lbs. / M'
92282S
2
.045"
.280"
40
92283S
3
.045"
.290"
49
92284S
4
.045"
.310"
58
92285S
5
.045"
.340"
70
92287S
7
.045"
.370"
89
92289S
9
.045"
.462"
121
922812S
12
.045"
.520"
160
922819S
19
.060"
.650"
245
922825S
25
.060"
.690"
270
922837S
37
.060"
.740"
365

16 AWG - Stranding Bare Copper - Get Quote
P/N # Of Cond. Nom. Insulation
Thickness (Inches)
Nom. O.D. (inches) Lbs. / M'
92262S
2
.045"
.300"
52
92263S
3
.045"
.320"
63
92264S
4
.045"
.350"
77
92265S
5
.045"
.370"
91
92267S
7
.045"
.410"
119
92269S
9
.045"
.470"
150
922612S
12
.045"
.510"
185
922619S
19
.060"
.675"
300
922625S
25
.060"
.727"
377
922637S
37
.080"
.945"
595

14 AWG - Stranding Bare Copper - Get Quote
P/N # Of Cond. Nom. Insulation
Thickness (Inches)
Nom. O.D. (inches) Lbs. / M'
92242S
2
.045"
.330"
67
92243S
3
.045"
.350"
84
92244S
4
.045"
.380"
104
92245S
5
.045"
.400"
123
92247S
7
.045"
.440"
161
92249S
9
.060"
.528"
215
922412S
12
.060"
.635"
285
922415S
15
.060"
.695"
360
922419S
19
.080"
.750"
415
922425S
25
.080"
.804"
529
922437S
37
.080"
1.02"
810

12 AWG - Stranding Bare Copper - Get Quote
P/N # Of Cond. Nom. Insulation
Thickness (Inches)
Nom. O.D. (inches) Lbs. / M'
92222S
2
.045"
.370"
93
92223S
3
.045"
.390"
120
92224S
4
.045"
.420"
150
92225S
5
.045"
.550"
185
92227S
7
.045"
.600"
235
92229S
9
.060"
.655"
315
922212S
12
.060"
.685"
377
922219S
19
.060"
.800"
568
922225S
25
.080"
.958"
790
922237S
37
.080"
1.10"
1100

10 AWG - Stranding Bare Copper - Get Quote
P/N # Of Cond. Nom. Insulation
Thickness (Inches)
Nom. O.D. (inches) Lbs. / M'
92202S
2
.045"
.430"
133
92203S
3
.045"
.460"
174
92204S
4
.045"
.500"
216
92205S
5
.060"
.625"
290
922012S
12
.080"
.820"
580