Picture of Type W Single Conductor Cable Type W Single Conductor Cable 90°C - 600 to 2000 Volt - UL

Type W Single Conductor Cable is used for a variety of applications from heavy duty temporary to permanent use where maximum resistance to fatigue is required. Systek Cable stocks an array of Type W Cable from the nation’s premier manufacturers for your demanding application

Construction
Conductor: - Fully annealed stranded bare copper.
8 AWG stranding (168)
6 AWG stranding (266)
4 AWG stranding (420)
2 AWG stranding (651)
1 AWG stranding (259)
1/0 AWG stranding (1064)
2/0 AWG stranding (1311)
3/0 AWG stranding (259)
4/0 AWG stranding (2090)
250 AWG stranding (629)
350 AWG stranding (888)
500 AWG stranding (1221)
750 AWG stranding (427)
Insulation: - Color Coded EPR.
Jacket: - Heavy duty thermoset CPE, -40°C to +90°C.
Applications: - Mining and Earth moving equipment.
Cranes, conveyors, and mobile equipment.
Portable Power Systems
Marine and shipyard industry
Oil and Gas Drilling Rigs
Suitable for continued immersion in water.
Features: - Good impact resistance.
Withstands severe environmental conditions.
Excellent resistance to heat, acids, oil, moisture, and most chemicals.
Ropeplay stranding for maximum flexibility.
Standards: - ICEA S-75-381
NEMA WC-58.
UL Type W
UL Type RHH or RHW
MSHA Approved.

8 AWG - Stranding Bare Copper (168) - Get Quote
P/N Nom. Jacket
Thickness (Inches)
Nom. O.D. (inches) Allowable Ampacity Lbs. / M'
92108
.060"
.440"
80
155

6 AWG - Stranding Bare Copper (266) - Get Quote
P/N Nom. Jacket
Thickness (Inches)
Nom. O.D. (inches) Allowable Ampacity Lbs. / M'
92106
.060"
.535"
105
267

4 AWG - Stranding Bare Copper (420) - Get Quote
P/N Nom. Jacket
Thickness (Inches)
Nom. O.D. (inches) Allowable Ampacity Lbs. / M'
92104
.060"
.600"
140
369

2 AWG - Stranding Bare Copper (651) - Get Quote
P/N Nom. Jacket
Thickness (Inches)
Nom. O.D. (inches) Allowable Ampacity Lbs. / M'
92102
.060"
.630"
190
458

1 AWG - Stranding Bare Copper (259) - Get Quote
P/N Nom. Jacket
Thickness (Inches)
Nom. O.D. (inches) Allowable Ampacity Lbs. / M'
92101
.080"
.745"
223
475

1/0 AWG - Stranding Bare Copper (1064) - Get Quote
P/N Nom. Jacket
Thickness (Inches)
Nom. O.D. (inches) Allowable Ampacity Lbs. / M'
92110
.080"
.775"
260
658

2/0 AWG - Stranding Bare Copper (1311) - Get Quote
P/N Nom. Jacket
Thickness (Inches)
Nom. O.D. (inches) Allowable Ampacity Lbs. / M'
92120
.080"
.815"
300
730

3/0 AWG - Stranding Bare Copper (259) - Get Quote
P/N Nom. Jacket
Thickness (Inches)
Nom. O.D. (inches) Allowable Ampacity Lbs. / M'
92130
.080"
.910"
345
805

4/0 AWG - Stranding Bare Copper (2090) - Get Quote
P/N Nom. Jacket
Thickness (Inches)
Nom. O.D. (inches) Allowable Ampacity Lbs. / M'
92140
.080"
.930"
405
1049

250 AWG - Stranding Bare Copper (629) - Get Quote
P/N Nom. Jacket
Thickness (Inches)
Nom. O.D. (inches) Allowable Ampacity Lbs. / M'
921250
.095"
1.08"
455
1425

350 AWG - Stranding Bare Copper (888) - Get Quote
P/N Nom. Jacket
Thickness (Inches)
Nom. O.D. (inches) Allowable Ampacity Lbs. / M'
921350
.095"
1.20"
570
1971

500 AWG - Stranding Bare Copper (1221) - Get Quote
P/N Nom. Jacket
Thickness (Inches)
Nom. O.D. (inches) Allowable Ampacity Lbs. / M'
921500
.095"
1.34"
700
2651

750 AWG - Stranding Bare Copper (427) - Get Quote
P/N Nom. Jacket
Thickness (Inches)
Nom. O.D. (inches) Allowable Ampacity Lbs. / M'
921750
.110"
1.56"
805
3305


Quick Quote
   Your Name*

   Company Name*

   Email*

   Phone*

   Cable Type*

   Gauge Size (AWG)*
   # of Conductors*

   Quantity in Feet*
   Comments