Picture of Stage Lighting Cable Stage Lighting Cable 105°C - 600 Volt

Systek Cable stocks a large inventory of Type SC Stage Lighting Cable. Type SC Cable (commonly referred to as Entertainment or Stage Cable) is recommended for temporary portable power and lighting applications in the entertainment industry including theatre, television and film. This extremely durable and flexible cable can be submerged in the water and is able to withstand stand temperatures from 105°C to -50°C.

Construction
Conductor:
-
Separator:
-
Polyester tape
Jacket:
-
Special heavy duty, EP/CP Jacket, Oil resistant and flame retardant.
Applications:
-
Portable power systems

Entertainment industry activities such as; theatre, television, night clubs, motion pictures, mobile communication vans, spotlights and sounds systems.

Other similar applications that would require temporary power.
Features:
-
Water resistant

Sunlight resistant

Designed to withstand severe environmental conditions.

Withstands exposure to oil, acids, alkalis, heat, flame, moisture and chemicals.

Meets or exceeds flame test requirements of MSHA, CSA and UL.
Industry Approvals:
-
UL Listed
CSA Certified

6 AWG - Stranding Bare Copper (259) - Get Quote
P/N Nom. Jacket
Thickness (Inches)
Nom. O.D. (inches) Allowable Ampacity Lbs. / M'
84606
.070"
.333"
105
118

4 AWG - Stranding Bare Copper (418) - Get Quote
P/N Nom. Jacket
Thickness (Inches)
Nom. O.D. (inches) Allowable Ampacity Lbs. / M'
84604
.070"
.387"
140
175

2 AWG - Stranding Bare Copper (660) - Get Quote
P/N Nom. Jacket
Thickness (Inches)
Nom. O.D. (inches) Allowable Ampacity Lbs. / M'
84602
.070"
.458"
190
260

1 AWG - Stranding Bare Copper (836) - Get Quote
P/N Nom. Jacket
Thickness (Inches)
Nom. O.D. (inches) Allowable Ampacity Lbs. / M'
84601
.090"
.543"
220
342

1/0 AWG - Stranding Bare Copper (1056) - Get Quote
P/N Nom. Jacket
Thickness (Inches)
Nom. O.D. (inches) Allowable Ampacity Lbs. / M'
84610
.090"
.575"
260
416

2/0 AWG - Stranding Bare Copper (1320) - Get Quote
P/N Nom. Jacket
Thickness (Inches)
Nom. O.D. (inches) Allowable Ampacity Lbs. / M'
84620
.090"
.626"
230
508

3/0 AWG - Stranding Bare Copper (1672) - Get Quote
P/N Nom. Jacket
Thickness (Inches)
Nom. O.D. (inches) Allowable Ampacity Lbs. / M'
84630
.090"
.678"
350
627

4/0 AWG - Stranding Bare Copper (2090) - Get Quote
P/N Nom. Jacket
Thickness (Inches)
Nom. O.D. (inches) Allowable Ampacity Lbs. / M'
84640
.090"
.741"
405
768


Quick Quote
   Your Name*

   Company Name*

   Email*

   Phone*

   Cable Type*

   Gauge Size (AWG)*
   # of Conductors*

   Quantity in Feet*
   Comments