Picture of DLO Cable DLO Cable (Diesel Locomotive) 600 to 2000 Volts - 90°C
UL RHH/RHW.CSA R90

DLO (Diesel Locomotive Cable) provided by Systek Cable is designed for wiring railroad cars and diesel-electric locomotives. This highly flexible 600V/2000V portable cord may also be used for cranes, motor leads, power jumpers, hoists, electrical equipment, drilling rigs and diesel generators with the ability to sustain safe electrical integrity in the harshest environments These cables are highly heat, oil and moisture- resistant, extremely flexible and are able to sustain 75 °C wet / 90 °C dry operating temperatures.

Construction
Conductor:
-
Insulation:
-
Premium Grade 90°C EPDM or EPR/HYP 2KV
Separator:
-
Suitable separator is applied between the conductor and insulation for easy stripping.
Jacket:
-
Heavy Duty Thermoset or CSPE
Applications:
-
Diesel electric locomotives, oil and gas drilling rigs, general shipyard use, mining and earth moving equipment.
Generally use at voltages up to 2kV where flexibility and portability are required.
Excellent for use in heavy flexing applications as a motor or apparatus lead.
Standards
-
UL Listed and Non UL Listed Available
1/0 AWG and higher - CT Rated
OSHA Acceptable and MSHA Approved

8 AWG - Stranding Bare Copper (37) - Get Quote
P/N Nom. Insulation
Thickness (Inches)
Nom. Jacket
Thickness (Inches)
Nom. O.D. (inches) Allowable Ampacity Lbs. / M'
3274
.045"
.030"
.330"
83
90

6 AWG - Stranding Bare Copper (61) - Get Quote
P/N Nom. Insulation
Thickness (Inches)
Nom. Jacket
Thickness (Inches)
Nom. O.D. (inches) Allowable Ampacity Lbs. / M'
3275
.060"
.030"
.410"
109
140

4 AWG - Stranding Bare Copper (105) - Get Quote
P/N Nom. Insulation
Thickness (Inches)
Nom. Jacket
Thickness (Inches)
Nom. O.D. (inches) Allowable Ampacity Lbs. / M'
3277
.060"
.030"
.460"
145
200

2 AWG - Stranding Bare Copper (154) - Get Quote
P/N Nom. Insulation
Thickness (Inches)
Nom. Jacket
Thickness (Inches)
Nom. O.D. (inches) Allowable Ampacity Lbs. / M'
3279
.060"
.030"
.520"
192
290

1 AWG - Stranding Bare Copper (224) - Get Quote
P/N Nom. Insulation
Thickness (Inches)
Nom. Jacket
Thickness (Inches)
Nom. O.D. (inches) Allowable Ampacity Lbs. / M'
3280
.080"
.045"
.649"
223
450

1/0 AWG - Stranding Bare Copper (280) - Get Quote
P/N Nom. Insulation
Thickness (Inches)
Nom. Jacket
Thickness (Inches)
Nom. O.D. (inches) Allowable Ampacity Lbs. / M'
3281
.080"
.045"
.680"
258
520

2/0 AWG - Stranding Bare Copper (329) - Get Quote
P/N Nom. Insulation
Thickness (Inches)
Nom. Jacket
Thickness (Inches)
Nom. O.D. (inches) Allowable Ampacity Lbs. / M'
3282
.080"
.045"
.718"
298
590

3/0 AWG - Stranding Bare Copper (456) - Get Quote
P/N Nom. Insulation
Thickness (Inches)
Nom. Jacket
Thickness (Inches)
Nom. O.D. (inches) Allowable Ampacity Lbs. / M'
3283
.080"
.045"
.810"
345
780

4/0 AWG - Stranding Bare Copper (551) - Get Quote
P/N Nom. Insulation
Thickness (Inches)
Nom. Jacket
Thickness (Inches)
Nom. O.D. (inches) Allowable Ampacity Lbs. / M'
3284
.080"
.045"
.838"
400
980

262.6 AWG - Stranding Bare Copper (650) - Get Quote
P/N Nom. Insulation
Thickness (Inches)
Nom. Jacket
Thickness (Inches)
Nom. O.D. (inches) Allowable Ampacity Lbs. / M'
3285
.095"
.065"
.955"
458
1130

313.1 AWG - Stranding Bare Copper (775) - Get Quote
P/N Nom. Insulation
Thickness (Inches)
Nom. Jacket
Thickness (Inches)
Nom. O.D. (inches) Allowable Ampacity Lbs. / M'
3286
.095"
.065"
1.04"
514
1300

373.3 AWG - Stranding Bare Copper (925) - Get Quote
P/N Nom. Insulation
Thickness (Inches)
Nom. Jacket
Thickness (Inches)
Nom. O.D. (inches) Allowable Ampacity Lbs. / M'
3287
.095"
.065"
1.15"
574
1570

444.4 AWG - Stranding Bare Copper (1100) - Get Quote
P/N Nom. Insulation
Thickness (Inches)
Nom. Jacket
Thickness (Inches)
Nom. O.D. (inches) Allowable Ampacity Lbs. / M'
3288
.095"
.065"
1.25"
642
1850

535 AWG - Stranding Bare Copper (1313) - Get Quote
P/N Nom. Insulation
Thickness (Inches)
Nom. Jacket
Thickness (Inches)
Nom. O.D. (inches) Allowable Ampacity Lbs. / M'
3289
.110"
.065"
1.305"
725
2110

777.7 AWG - Stranding Bare Copper (1925) - Get Quote
P/N Nom. Insulation
Thickness (Inches)
Nom. Jacket
Thickness (Inches)
Nom. O.D. (inches) Allowable Ampacity Lbs. / M'
3291
.120"
.065"
1.55"
910
3050

929.2 AWG - Stranding Bare Copper (2318) - Get Quote
P/N Nom. Insulation
Thickness (Inches)
Nom. Jacket
Thickness (Inches)
Nom. O.D. (inches) Allowable Ampacity Lbs. / M'
3293
.120"
.065"
1.65"
1025
3725


Quick Quote
   Your Name*

   Company Name*

   Email*

   Phone*

   Cable Type*

   Gauge Size (AWG)*
   # of Conductors*

   Quantity in Feet*